    • Product Name: Luxi Chemical Group Isopropyl Alcohol Electronic Grade
    • Factroy Site: Binhai New Area, Tianjin, China
    • Price Inquiry: sales4@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 845640
    Product Name Isopropyl Alcohol Electronic Grade
    Manufacturer Luxi Chemical Group
    Grade Electronic Grade
    Cas Number 67-63-0
    Chemical Formula C3H8O
    Molecular Weight 60.10 g/mol
    Appearance Clear colorless liquid
    Odor Characteristic alcohol odor
    Purity ≥99.99%
    Water Content ≤100 ppm
    Boiling Point 82.5 °C at 101.3 kPa
    Melting Point -89 °C
    Flash Point 11.7 °C (closed cup)
    Density 0.786 g/cm³ at 20 °C
    Refractive Index 1.377 at 20 °C
    Vapor Density 2.1 (air=1)
    Evaporation Rate 1.7 (butyl acetate=1)

    As an accredited Luxi Chemical Group Isopropyl Alcohol Electronic Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Electronic grade isopropyl alcohol from Luxi Chemical Group is packaged in sealed 200-liter steel drums, 160 kg per drum.
    Container Loading (20′ FCL) Container Loading (20′ FCL): Electronic-grade isopropyl alcohol is safely secured in a sealed 20-foot container, preventing contamination for shipment.
    Shipping Luxi Chemical Group’s Electronic Grade Isopropyl Alcohol ships in dedicated, contamination-free stainless steel or HDPE containers under inert gas blanketing to preserve ultrapurity. Temperature-controlled, secured transport prevents moisture ingress and static hazards. Full documentation, traceability, and strict regulatory compliance ensure safe, clean delivery to semiconductor and electronics manufacturing facilities.
    Storage Store in a clean, tightly sealed, dedicated container to preserve electronic-grade purity. Keep in a cool, dry, well-ventilated area, away from heat, sparks, open flames, and oxidizing agents. Protect from moisture, dust, and contamination. Use grounded equipment and follow static-safe handling procedures to maintain solvent quality and safety.
    Shelf Life Shelf life is typically 12 months from production date when stored sealed in original containers under cool, dry conditions.
    Application of Luxi Chemical Group Isopropyl Alcohol Electronic Grade

    Why Is Post-CMP Wafer Drying Treated as a Surface-Tension-Governed Unit Operation?

    Post-CMP drying of 300 mm silicon wafers converts a liquid-laden surface carrying residual slurry particles, corrosion inhibitors, and adsorbed moisture into a water-free state without leaving ionic residues. The unit operation is governed by the surface-tension differential created when electronic-grade isopropyl alcohol vapour adsorbs at the three-phase meniscus of ultrapure water during wafer withdrawal. Luxi Chemical Group electronic-grade IPA supplied under lot-specific certificates aligned to SEMI C35-0708 and ASTM D770-21 is vaporised into heated nitrogen at 1.0–4.0 vol% concentration. Single-wafer spin tools dispense the liquid at 100 vol% during the low-speed rinse phase at 0.5–1.0 L/min for 20–40 s. The production process includes an immersion rinse in ultrapure water followed by IPA-assisted Marangoni drying in a chamber where nitrogen at 20–40 L/min is sparged through a heated IPA reservoir maintained at 60–80 °C. The wafer is withdrawn at controlled speed, and the surface-tension gradient at the meniscus removes the water film without allowing watermarks to form. The operational window is narrow: below 1.0 vol% IPA vapour, the drying meniscus is unstable and particle-laden water droplets remain; above 6.0 vol%, condensation creates solvent films that can redeposit nonvolatile residues. In high-aspect-ratio through-silicon via and 3D NAND structures with critical dimensions below 60 nm, capillary forces during rinse/drying can cause line collapse; the replacement of water with IPA vapour reduces capillary pressure because the liquid surface tension is lowered from 72 mN/m to approximately 21–23 mN/m, but the wafer must enter the drying chamber without bulk liquid pooling. The spinner speed during liquid IPA dispense is reduced to 300–500 rpm to limit aerosol formation and then ramped to 1500–2500 rpm for spin-off. Exhaust flow is interlocked with the IPA reservoir temperature controller; if the IPA vapour concentration drifts outside the 1.0–4.0 vol% window, the tool aborts the drying sequence and recirculates the cassette through a deionized-water rinse to prevent watermark defects. Batch-to-batch variance is observed when the IPA reservoir is not replenished after 24 h of open-top operation because atmospheric water uptake alters the evaporation rate. Terminal finished product types include logic processors, DRAM, 3D NAND, and power management ICs fabricated on 300 mm silicon substrates. The use of electronic-grade IPA with water content not exceeding 0.10 mass% and metal ion limits aligned to SEMI C35 prevents boron, phosphorus, and calcium residues from affecting gate oxide integrity.

    Compliance checklist for electronic-grade IPA critical cleaning applications
    ParameterTest methodLimit
    AssaySEMI C35-0708, ASTM D770-21≥ 99.8 mass%
    WaterASTM D1364≤ 0.10 mass%
    Non-volatile residueASTM D1353≤ 5 ppm
    ChlorideSEMI C35≤ 0.2 ppm
    SulfateSEMI C35≤ 0.5 ppm
    PCBA post-clean ionic contaminationIPC-TM-650 2.3.25< 1.56 µg NaCl/cm²

    In lithography track coater cups, electronic-grade IPA is dispensed as the final low-residue rinse after edge-bead removal solvents have dissolved the resist bead at the wafer bevel. The compliance framework includes SEMI C35-0708, SEMI S2 equipment safety, ISO 14644-1 Class 5 cleanroom operation, and photoresist supplier-defined metal and particle specifications. The formulation addition ratio is 100 vol% electronic-grade IPA for the rinse nozzle, while upstream solvent blends used for edge-bead dissolution may contain 5–20 vol% IPA mixed with PGMEA or cyclohexanone to adjust evaporation rate and resist swelling. The downstream production process is an inline coater/developer track with an edge-bead removal nozzle scanning the wafer periphery at 0.3–1.0 mL dispensed volume per edge-segment, followed by a 3–10 s IPA rinse and a spin-dry at 1500–2500 rpm to remove dissolved resist and residual solvent. Inline coater/developer tracks use a separate solvent cabinet with nitrogen blanket at 5–10 kPa overpressure; the nozzle tip is positioned 0.5–1.0 mm from the bevel to avoid back-spray onto the central die array. A known failure mode occurs when exhaust extraction flow drops below 50 m³/h, causing IPA vapour to accumulate around the resist spin bowl and alter the local evaporation rate of the photoresist, which produces edge build-up. Terminal finished product types include advanced-node microprocessors, DRAM, NAND flash, and CMOS image sensor wafers. Because IPA is hygroscopic, open coater cups in humid cleanrooms above 55% RH accumulate water; the solvent must be replenished or nitrogen-blanketed to maintain water content below 0.10 mass%. Uncontrolled mixing with acetone should be avoided because rapid evaporative cooling can condense moisture and cause localized resist redeposition.

    Large-Area Display Array Cleaning and Drying before CVD

    Gen 8.5 and Gen 10.5 substrate lines that process indium tin oxide and low-temperature polysilicon backplanes require organic-free surfaces before chemical vapour deposition; the use of electronic-grade IPA in the final rinse step lowers the vapour-liquid interfacial tension of the rinsing film and prevents water spotting on 2200 mm × 2500 mm glass. The applicable standards are SEMI C35-0708, ASTM D770-21, and ISO 14644-1 Class 6 cleanroom limits for airborne particles. The formulation addition ratio in the ultrasonic cleaning bath is 5–15 vol% IPA in ultrapure water, while the final low-tension rinse before the vacuum bake uses 100 vol% electronic-grade IPA dispensed at 2–5 mL per substrate side. The production process includes a 40 kHz/80 kHz dual-frequency ultrasonic clean, air-knife pre-drying, then an IPA final rinse to reduce water contact angle below before gate-insulator or buffer-layer deposition. Dual-frequency ultrasonic transducers at 40 kHz for larger particles and 80 kHz for sub-micrometre particles are calibrated with hydrophone power density at 10–30 W/L; cavitation levels above 30 W/L can damage indium tin oxide lines. The final IPA rinse is followed by a vacuum bake at 120–150 °C for 5–10 min to desorb solvent and water from the glass surface before sputtering. Terminal finished product types include thin-film-transistor LCDs, AMOLED panels, automotive displays, and microLED display backplanes. The critical limitation is the 12 °C flash point of IPA; heated tanks and ultrasonic transducers must be equipped with vapour monitoring and exhaust air exchange above 8–10 changes/min to keep vapour concentration below 25% of the lower flammable limit.

    Lithium-ion cell assembly lines introduce electronic-grade IPA at the transition from tab pre-welding to electrolyte filling, where copper and aluminium collector surfaces must be free of micro-particulate and organic films before the LiPF6 electrolyte is metered into the cell. The applicable compliance system comprises ISO 16232:2018 for component cleanliness, ISO 14644-1 Class 6 dry-room particle control, and IATF 16949 clause 8.6 for product-release control. The solvent is used neat at 100 vol%, with a dispensed volume of 0.05–0.15 mL per cell side for pouch-cell tab cleaning; ultrasonic immersion tanks maintain 100 vol% electronic-grade IPA with a maximum water content of 0.10 mass% because moisture reacts with LiPF6 to generate hydrofluoric acid. The production sequence includes ultrasonic cleaning at 30–45 °C and 40 kHz, followed by vacuum drying at 60–80 °C under -0.095 MPa for 2–4 h to remove IPA and absorbed water before electrolyte injection. In cylindrical cell tab cleaning, the tab is dipped for 10–30 s; ultrasonic tank bath life is monitored by particle counting and the bath is replaced when particles at or above 0.5 µm exceed 500 particles/L. Moisture ingress from open IPA containers remains a leading source of batch rejection; headspace vapour purged with nitrogen at 2–5 L/min is used for solvent storage. Terminal finished product types include prismatic, pouch, and cylindrical lithium-ion cells for electric vehicles, energy storage systems, and portable electronics. A process incompatibility exists with natural rubber and some acrylic enclosure materials; stainless steel or high-density polyethylene tanks and lines are preferred because IPA can extract plasticizers from flexible polyvinyl chloride tubing and create particulate defects.

    When Electronic-Grade IPA Replaces Halogenated Solvents in PCBA Stencil Cleaning

    Stencil cleaning after solder paste printing represents a high-frequency recovery operation in surface-mount assembly; an electronic-grade IPA stream can be substituted for n-propyl bromide or trichloroethylene in closed cabinet systems if the flash-point constraints and ionic-cleanliness endpoints are quantified. The compliance framework is IPC J-STD-001H for soldered electronic assemblies, IPC-A-610G for acceptance criteria, and IPC-TM-650 2.3.25 for residual ionic contamination measured by resistometric ROSE testing. The formulation addition ratio is 100 vol% electronic-grade IPA in dedicated stainless-steel spray cabinets for underscreen stencil cleaning; aqueous compatibilised formulas used in understencil wipe rolls can operate at 10–30 vol% IPA blended with 2–5 vol% glycol ether co-solvent and ultrapure water. The production process includes a pneumatic spray at 0.2–0.6 MPa, soft-bristle understencil roll wiping, and a final dry vacuum pass; cleaned stencils are returned immediately to the solder paste printer to minimize exposure to ambient humidity. Understencil roll wipe pressures between 0.15 MPa and 0.35 MPa are selected for fine-pitch apertures below 0.3 mm; excessive pressure deforms stencil webs while insufficient pressure leaves solder paste in aperture sidewalls. Solvent replacement frequency in the stencil cleaner sump is based on specific gravity or refractive index drift; if IPA concentration falls below 85 vol% due to moisture or flux pickup, cleaning efficacy drops. Terminal finished product types include automotive ECU, power-conversion modules, 5G base-station transceivers, and industrial motor-control boards. Because IPA residues are limited but not zero, post-reflow assemblies must be verified by IPC-TM-650 2.3.25 with an acceptance threshold below 1.56 µg NaCl/cm²; polymerized no-clean flux residues may require a saponifier prewash before IPA rinsing.

    Precision Optical Bonding and Sensor Cover Glass Preparation with Electronic-Grade IPA

    Cleaning of CMOS image sensor cover glass, infrared cut filters, and LiDAR windows prior to adhesive bonding requires a final rinse solvent that evaporates without leaving sub-0.5 µm particle residues; electronic-grade IPA is applied in a two-stage sequence of diluted particulate removal and neat low-moisture rinse. The relevant standards include ISO 10110-7 for surface imperfection characterization, MIL-PRF-13830B scratch-dig designations for precision optics, ISO 14644-1 Class 5 cleanroom operation, and SEMI C35-0708 solvent purity. The formulation addition ratio is 70 vol% electronic-grade IPA / 30 vol% ultrapure water for particulate removal, followed by a 100 vol% electronic-grade IPA rinse dispensed at 0.2–0.5 mL per optic. The production process includes 40 kHz ultrasonic cleaning, a heated vapour degreaser with electronic-grade IPA at 60–80 °C vapour zone, condensation rinse, and dry nitrogen blow-off at 0.3–0.5 MPa before plasma activation or adhesive dispensing. In a vapour degreaser, the cooling-coil temperature is maintained between 10 °C and 20 °C to condense IPA at the freeboard; freeboard ratio is kept above 0.75 to reduce vapour loss. Residual hydrocarbon films are measured by water contact angle; a post-rinse contact angle below 10° is typically required before plasma activation and adhesive dispensing. Terminal finished product types include mobile-phone camera modules, ADAS cameras, lidar sensors, endoscopes, and augmented-reality optical combiners. Compatibility testing per ASTM D543 is recommended for coated polymeric lenses because IPA can cause crazing in acrylic and stress cracking in polycarbonate at production temperatures above 40 °C.

    Free Quote

    Competitive Luxi Chemical Group Isopropyl Alcohol Electronic Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: sales4@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Luxi Chemical Group Isopropyl Alcohol Electronic Grade (CAS 67-63-0) is supplied as a single-component, high-purity 2-propanol for semiconductor, flat-panel display, printed circuit board, and photomask manufacturing. The product is not assigned a proprietary model number in public technical documentation; procurement is by electronic-grade designation and applicable SEMI C41 category for 2-propanol. Representative specification documents for this solvent class list assay at ≥ 99.95 wt%, water at ≤ 0.01 wt%, non-volatile residue at ≤ 5 mg/kg, and critical alkali and transition metal concentrations at ≤ 1 µg/kg by ICP-MS. The material is manufactured by catalytic hydrogenation of acetone followed by multi-stage distillation, extractive drying, and sub-micrometre filtration. Compared with technical-grade isopropyl alcohol, the electronic-grade material is differentiated by lower water content, lower evaporation residue, controlled particle burden, and specified trace metal limits required for cleaning steps in advanced lithography and wet etch sequences.

    The bulk physical properties govern handling and process design. The molecular formula is C3H8O with molar mass 60.10 g/mol, boiling point 82.5 °C, density 0.786 g/cm³ at 20 °C, and closed-cup flash point 11.7 °C. Vapour pressure is 4.4 kPa at 20 °C, and the lower flammable limit in air is 2.0 vol%. These constants place the solvent in flammable-liquid storage categories governed by NFPA 30 and equivalent regional fire codes. The product is packaged in high-density polyethylene drums or stainless steel totes cleaned to low extractable levels; headspace is nitrogen-blanketed to maintain the water specification during storage and shipment.

    Which specification boundary separates electronic-grade IPA from technical and reagent solvent grades?

    The dominant boundaries are water, non-volatile residue, and trace metal burden. Technical-grade 2-propanol is commonly supplied with water below 0.2 wt%, residue below 50 mg/kg, and cation concentrations in the low mg/kg range. Semiconductor-grade material is instead held to water ≤ 0.01 wt% and residue ≤ 5 mg/kg; sodium, potassium, iron, copper, and aluminum are each controlled at ≤ 1 µg/kg. These limits are measured by ASTM E203 water titration, ASTM D1353 residue gravimetry, and ICP-MS. The controlling semiconductor standard is SEMI C41, which establishes impurity categories for 2-propanol used in wafer cleaning. The distinction is practical: in a spin-rinse-dry tool, technical IPA with 50 mg/kg residue can leave visible organic haze after wafer drying, whereas electronic-grade material under the same tool recipe is specified to avoid that residue-driven failure mode.

    Table 1. Representative electronic-grade IPA specification band; not a Luxi batch-specific certificate
    ParameterRepresentative electronic-grade limitTest method
    2-Propanol assay≥ 99.95 wt%Capillary GC, area percent
    Water≤ 0.01 wt%ASTM E203, Karl Fischer
    Non-volatile residue≤ 5 mg/kgASTM D1353
    Acidity as acetic acid≤ 5 mg/kgASTM D1613
    Colour, APHA≤ 10ASTM D1209
    Density at 20 °C0.785–0.787 g/cm³ASTM D4052
    Chloride≤ 0.1 mg/kgIon chromatography
    Na, K, Fe, Cu, Al≤ 1 µg/kg eachICP-MS
    Particles ≥ 0.2 µm≤ 25 particles/mLLaser particle counter

    In front-end wafer processing, the solvent is dispensed through 0.05 µm point-of-use filters on single-wafer cleaning platforms. Dispense temperature is usually 10–15 °C for Marangoni drying assistance, although tool recipes vary. The surface tension of isopropyl alcohol is 21.7 mN/m at 20 °C, compared with 72.8 mN/m for water; this lower surface tension reduces capillary forces during rinse-water removal from high-aspect-ratio photoresist patterns and silicon trenches. In immersion baths, the product is used as a final rinse after SC1/SC2 cleans to displace water and prevent drying residues. The electronic-grade specification is relevant because ionic contamination introduced at this stage can persist into gate dielectric deposition and degrade device yield.

    Trace-metal retention in the drying meniscus, not bulk assay alone, controls final wafer cleanliness

    During Marangoni drying, a concentration gradient of 2-propanol at the water meniscus creates a surface-tension gradient that pulls the meniscus across the wafer. If the IPA feed contains more than 0.02 wt% water, the gradient weakens and the drying front can leave watermarks at the wafer edge. Metal impurities are not vaporized with IPA; they remain in the liquid phase and can deposit on the substrate if the solvent is allowed to evaporate without displacement. On 300 mm single-wafer chambers, IPA is typically introduced at 0.5–2.0 L/min through 0.05 µm filtration, although tool-specific recipes vary. Published data for Luxi-specific drying performance in mixed IPA/water systems is limited; process risk is therefore controlled by the cited water and metal specifications rather than by additive chemistry.

    Printed circuit board assembly uses the same solvent for rosin flux removal in spray-in-air and ultrasonic stencil-cleaning equipment. The absence of significant non-volatile residue is critical because post-clean ionic contamination is measured by resistivity of solvent extract per IPC-TM-650 2.3.25. Technical IPA can carry ionic residues that lower measured resistivity and raise the risk of electrochemical migration. Electronic-grade IPA is specified when surface insulation resistance after cleaning must remain stable at 85 °C and 85% RH bias testing. In this application, the difference between electronic and technical grades is not cleaning speed but ionic cleanliness after evaporation.

    When the product is stored outside nitrogen-blanketed containers, water uptake becomes the dominant specification risk

    Isopropyl alcohol is hygroscopic. Bulk storage in unsealed HDPE containers at relative humidity above 60% can increase water content by 0.005–0.02 wt% per day depending on headspace exchange. Transfer into process tools should use dry nitrogen with a dew point below −40 °C and closed-loop dispensing. Wetted transfer lines are typically 316L stainless steel or fluoropolymer; copper alloys are avoided where trace chloride may be present because chloride-induced corrosion can release metal ions into the solvent. The product is incompatible with strong oxidizers, acid chlorides, isocyanates, and finely divided aluminium under contamination conditions. It is not packaged as sterile, and it is not intended for pharmaceutical API use unless a separate USP/NF or Ph.Eur. monograph is demonstrated.

    Batch-to-batch variance is controlled by continuous distillation, extractive drying, and final filter lot testing. Certificates of analysis report the actual water and metal concentrations for each packaged lot. Users managing multiple packaged lots should verify that antistatic or plasticizer residues from container liners do not appear in the non-volatile residue measurement. Shared distribution piping with technical-grade IPA is a known contamination failure mode; dedicated lines or validated line-cleaning procedures are required before electronic-grade material is introduced.

    Table 2. Comparative impurity profiles across common isopropyl alcohol grades
    ParameterElectronic gradeTechnical gradeReagent grade
    Water≤ 0.01 wt%≤ 0.2 wt%≤ 0.1 wt%
    Non-volatile residue≤ 5 mg/kg≤ 50 mg/kg≤ 10 mg/kg
    Critical metals≤ 1 µg/kg eachLow mg/kg rangeppm range
    Particle controlControlled at ≥ 0.2 µmNot specifiedNot semiconductor-controlled
    Primary specificationSEMI C41Supplier COAACS or equivalent monograph

    Flat-panel display cleaning lines use the same solvent in ultrasonic baths for glass substrates prior to indium tin oxide deposition. Cleanrooms handling the product are typically classified as ISO 14644-1 Class 5 or better to prevent particle recontamination. In photomask cleaning, residue above 5 mg/kg can redeposit on chromium surfaces during drying and appear as printable defects. Published data for Luxi-specific pinhole defect density in this configuration is limited; the specification package is therefore the primary control variable.

    Microelectromechanical systems release processes sometimes replace the final water rinse with IPA before air drying to prevent capillary collapse of released structures. The lower surface tension of IPA reduces the meniscus force on suspended features, but water entering the bath above 0.02 wt% can still create capillary bridges during final drying. Point-of-use verification of water and particle count is therefore applied on process tools where the solvent is used as a final rinse before vacuum or thermal processing.