| HS Code | 579565 |
| Chemical Name | Isopropyl Alcohol (2-Propanol) |
| Cas Number | 67-63-0 |
| Chemical Formula | C3H8O |
| Purity | ≥99.99% |
| Boiling Point | 82.5°C at 760 mmHg |
| Melting Point | -89.5°C |
| Density | 0.786 g/cm³ at 20°C |
| Flash Point | 11.7°C (closed cup) |
| Vapor Pressure | 33 mmHg at 20°C |
| Water Content | ≤0.01% |
| Assay | ≥99.99% (as Isopropyl Alcohol) |
| Acidity | ≤0.0002% (as Acetic Acid) |
| Nonvolatile Residue | ≤0.0005% |
| Metallic Impurities Control Limit | <0.1 ppb (per element) |
As an accredited LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged under nitrogen in cleanroom-sealed stainless steel containers, ensuring <0.1 PPB purity. Available in 20 liters. |
| Container Loading (20′ FCL) | Loading 20' FCL of ultra-pure isopropyl alcohol (electronic grade) requires clean, dry container to prevent contamination below 0.1 PPB control limit. |
| Shipping | Shipping requires strict contamination control to preserve ultra-pure grade (<0.1 PPB). The product is packaged in electro-polished, sealed containers under inert gas, ensuring integrity. Labeled as flammable liquid, transport follows hazardous materials regulations, with temperature stability and traceability documentation to prevent moisture or particulate contamination during transit. |
| Storage | Store in tightly sealed, high-purity containers (stainless steel or PFA) under inert nitrogen blanketing to prevent moisture and airborne contamination. Keep in a cleanroom or controlled environment, away from heat, sparks, and UV light. Use dedicated, grounded dispensing equipment. Maintain integrity to meet <0.1 PPB specifications and avoid contact with incompatible materials. |
| Shelf Life | Shelf life is typically 24 months from manufacture when stored sealed, away from light and moisture. |
In front-end integrated circuit fabrication, the final rinse preceding gate oxide growth uses LCY Chemical Corporation ultrapure 2-propanol with the supplier-controlled metal cation limit of 0.1 ppb to displace adsorbed water from high-aspect-ratio shallow trench isolation structures without adding ionic contamination. The cleaning sequence following dilute-HF etch or post-CMP oxide polish consists of an intermediate SC-1 bath at 65 ± 5 °C (NH₄OH/H₂O₂/H₂O at 1:1:5 by volume), an ultrapure-water overflow rinse at 22 ± 2 °C until the rinse stream resistivity stabilizes at 18.2 MΩ·cm, a low-flow SC-2 bath (HCl/H₂O₂/H₂O at 1:1:6), and a final rinse under the same resistivity endpoint. The 2-propanol is then delivered as a vapor phase in a single-wafer spin processor; the liquid is filtered through a 0.05 µm PTFE membrane and vaporized into nitrogen at 3–5 vol% under an oxygen-depleted enclosure maintained below 2% O₂. Wafer withdrawal from the final deionized-water meniscus is controlled at 0.5–2.0 mm/s while the surface-tension gradient generated by adsorbed 2-propanol reduces water surface tension from 72.8 mN/m toward 21.7 mN/m at 20 °C, which collapses the rinse-water meniscus without droplet nucleation on gate oxide surfaces. The drying step is conducted at 20 ± 2 °C for 120–180 s, with nitrogen flow at 8–12 L/min; oversaturation with 2-propanol during the first 5 s produces transient wetting that lowers contact angle below 10° on hydrophilic oxide and below 25° on hydrophobic nitride. Process line data indicate that 0.2–0.5% water uptake in the IPA vapor feed increases post-dry defect counts above the 0.15 µm particle threshold; therefore, the delivery vessel is blanketed with nitrogen and the cleanroom relative humidity is held below 55% when the vaporizer is online. The cleanliness specification is anchored to SEMI C63-1212 for trace-metal control in 2-propanol.
| Step | Temperature | Critical control parameter | Failure mode when exceeded |
|---|---|---|---|
| SC-1 megasonic bath | 65 ± 5 °C | 950 kHz transducer, 400 W | oxide microroughening above 70 °C |
| UPW overflow rinse | 22 ± 2 °C | endpoint resistivity 18.2 MΩ·cm | residual ammonium or chloride carryover |
| SC-2 ionic desorption | 60 ± 5 °C | HCl/H₂O₂/H₂O 1:1:6 | metal hydroxide precipitation if pH drifts |
| IPA vapor dry | 20 ± 2 °C | N₂ flow 8–12 L/min, withdrawal 0.5–2.0 mm/s | water mark formation if IPA injection falls below 3 vol% |
On advanced-node photomask cleaning lines, pellicle mounting of 6025 quartz reticles (152.4 mm × 152.4 mm × 6.35 mm) requires a final organic residue level below the detection threshold of low-flux TOF-SIMS because mobile ions trapped inside the pellicle cavity can migrate during ArF transmissive exposure. The ultrapure 2-propanol is used at full strength for a 10-second spray rinse of the patterned surface after piranha and SC-1 reticle cleaning, and the pellicle frame edge is then hand-swabbed with a 4:1 by volume ultrapure-water:IPA mixture to prevent softening of the pressure-sensitive acrylic adhesive. The cleaning hood operates at ISO 14644-1 Class 4, with HEPA-filtered downflow at 0.45 m/s. For hardened residue on the chrome border, a short 30-second immersion in undiluted 2-propanol at 22 °C is applied only after compatibility testing on the shielding frame, because prolonged contact with siloxane-based pellicle adhesives can extract low-molecular-weight fractions that later form haze on the ArF pellicle membrane. Final inspection is performed with a reticle blank inspection tool using 0.1 µm sensitivity; standard operating procedure rejects any reticle above 0.5 particles/cm² after pellicle mounting. Compliance for sub-mask cleanliness is anchored to SEMI C63-1212 for 2-propanol trace-metal limits and to ArF reticle cleanliness protocols for outgassing species; published numeric data for pellicle adhesive extraction in this specific configuration is limited.
Magnetic hard disk media prior to diamond-like carbon overcoat deposition are cleaned through a cascade of the present 0.1 ppb 2-propanol dispensed at 0.15–0.25 MPa from PTFE nozzle arrays. The substrate is a 0.635 mm thick glass blank or NiP-plated aluminum blank with 65 mm or 95 mm outer diameter. The cleaning step removes adsorbed plasticizer, fluorinated lubricant-free organics, and submicron alumina particles from the polished substrate after texture and laser zone test. A single-disk spin cleaner rotates at 3000 rpm while the 2-propanol is dispensed at 100% concentration for 20–30 s, followed by a 15-second ultrapure-water flush at the same rotational speed to avoid drying stains on NiP grain boundaries. Non-volatile residue after the combined sequence is monitored by gravimetric analysis per ASTM E1235; the production specification requires less than 0.5 µg/cm² on the final disk before sputtering the amorphous carbon overcoat. The same solvent is used on magnetic head sliders in the head-stack assembly area: a 0.3 mL dose is applied with a cleanroom polyester swab to the air bearing surface, and the slider is then blow-dried with filtered nitrogen at 0.2 MPa. Failure to control metal cations in this cleaning fluid produces a measurable increase in signal-to-noise dropout during spin-stand testing; therefore, the present 0.1 ppb limit is used for all disk and slider contact cleaning. The cleaning zone is maintained at ISO 14644-1 Class 4 and is separated from lubricant dip-coat stations to prevent back-diffusion of perfluoropolyether vapors onto the cleaned substrate.
The final wipe of a single-mode SC/APC connector end face before adhesive bonding is conducted with 100% ultrapure 2-propanol dispensed from a 0.1 µm filtered pump bottle to prevent microdent contamination on the 8.2 µm core region. The solvent is wicked onto a non-linting polyester foam swab and drawn across the ferrule in a single continuous motion; a second dry wipe removes any liquid meniscus. For cured epoxy residue on the sidewall of the ferrule bore, a 70:30 by volume 2-propanol:deionized-water mixture is used at 35 °C to lower the solvent evaporation rate and soften bisphenol-A epoxy without attacking the glass fiber cladding. A connector inspection microscope with IEC 61300-3-35 acceptance criteria is used to classify scratches, pits, and adsorbed stains; the production line rejects any end face with a non-volatile residue band wider than 5 µm or a scored region exceeding 10 µm in the core zone. After cleaning, connectors are dried with ultrapure nitrogen at 0.05 MPa for 3–5 s and mated immediately inside an ISO 14644-1 Class 5 splicing enclosure. The ionic cleanliness requirement for sealed connector packages is verified by ion chromatography of an extractive rinse; the acceptance limit for total anion residue is 0.5 µg/cm² as sodium chloride equivalent. Use of the present 0.1 ppb metal-cation 2-propanol avoids sodium and potassium migration that would otherwise reduce splice loss stability under damp-heat testing at 85 °C/85% RH per IEC 61300-2-21.
Release of sacrificial silicon dioxide from a MEMS accelerometer proof mass is performed in concentrated HF vapor followed by a six-cycle ultrapure-water rinse and then a closed-loop 2-propanol vapor drying sequence. The high-aspect-ratio cantilever comb structures, with gap widths from 1.5 µm to 2.5 µm and release length exceeding 50 µm, are prone to capillary stiction if water is allowed to evaporate inside the comb gaps. The present 0.1 ppb 2-propanol is heated to 45 °C in a quartz vapor generator and delivered with nitrogen at 3 L/min for 10–15 min while the chamber temperature is ramped from 25 °C to 55 °C at 5 °C/min. Condensation of 2-propanol on the released structures reduces the liquid surface tension to 21.7 mN/m at 20 °C, and the nitrogen displacement pushes the meniscus out of the comb gaps before drying. The principal batch failure mode is uneven condensation on high-mass proof-mass anchors; this is mitigated by maintaining the IPA vapor concentration at 8–10 vol% in nitrogen and by rotating the wafer at 10 rpm during the initial 2 min. The dried wafers are then transferred under dry nitrogen to the thin-film encapsulation cluster; exposure to cleanroom air above 40% RH is limited to less than 5 min because water re-adsorption on silicon dioxide sidewalls restores capillary force. Final stiction testing is performed by scanning electron microscopy and by electrical pull-in voltage measurement; a shift of pull-in voltage greater than 0.3 V relative to pre-release simulation indicates residual stiction. The resulting wafer-level packaged inertial sensor is then singulated and tested under 85 °C/85% RH environmental stress.
Deposition uniformity for e-beam evaporated multilayer coatings on laser optics degrades when sub-2 µm dust and adsorbed hydrocarbon films remain on fused silica substrates. A 30 vol% 2-propanol / 70 vol% ultrapure-water mixture is used in an ultrasonic bath at 40 kHz for 180 s followed by a 100% 2-propanol displacement rinse in a vapor degreaser configured for nonchlorinated solvents. The substrates are 25-mm fused silica or zinc selenide witness windows with λ/10 surface flatness at 632.8 nm; the cleaning bench is an ISO 14644-1 Class 5 laminar flow cabinet with 0.45 m/s downflow. After drying with filtered nitrogen, the surface is inspected by dark-field microscopy for particles larger than 1 µm; any component with more than 3 such particles per 25 mm diameter is returned to the ultrasonic line. Hydrocarbon removal is confirmed by FTIR absorption at the C–H stretch region around 2920 cm⁻¹, with acceptance below 0.1% reflectance loss on witness coupons. The cleaned substrates are loaded into an e-beam coating chamber within 15 min to avoid recontamination by cleanroom background siloxanes.
Class III implantable pulse generator electronics are cleaned in a two-stage inline spray system using a 75:25 by volume mixture of ultrapure 2-propanol and deionized water heated to 35 °C. The first spray stage at 689 kPa for 10 min removes rosin flux from fine-pitch QFN packages; the second stage applies 100% 2-propanol as a final rinse for 3 min to reduce ionic carryover. Post-clean ion contamination is measured by resistivity of solvent extract per IPC-TM-650 2.3.28 and must remain below 1.56 µg NaCl/cm² per IPC J-STD-001 Class III. The terminal assembly is sealed in a titanium can; ionic residues above this threshold have been correlated with dendrite growth under 85 °C/85% RH biased humidity testing.
Competitive LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: sales4@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
| Parameter | Value | Reference / test designation |
|---|---|---|
| CAS registry number | 67-63-0 | Chemical identity |
| Molecular formula | C3H8O | Chemical identity |
| Molar mass | 60.10 g/mol | Calculated from atomic weights |
| Density at 20°C | 0.785 g/mL | ASTM D4052 |
| Boiling point at 101.3 kPa | 82.5°C | Literature value |
| Closed-cup flash point | 12°C | ASTM D56 |
| Surface tension at 20°C | 21.7 mN/m | Literature value |
| Vapor pressure at 20°C | 4.4 kPa | Literature value |
| Trace-metal control limit | <0.1 ppb | ICP-MS after SEMI C12 sampling |