Ascent Petrochem Holdings Co., Limited

Products

LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade

    • Product Name: LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade
    • Factroy Site: Binhai New Area, Tianjin, China
    • Price Inquiry: sales4@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 579565
    Chemical Name Isopropyl Alcohol (2-Propanol)
    Cas Number 67-63-0
    Chemical Formula C3H8O
    Purity ≥99.99%
    Boiling Point 82.5°C at 760 mmHg
    Melting Point -89.5°C
    Density 0.786 g/cm³ at 20°C
    Flash Point 11.7°C (closed cup)
    Vapor Pressure 33 mmHg at 20°C
    Water Content ≤0.01%
    Assay ≥99.99% (as Isopropyl Alcohol)
    Acidity ≤0.0002% (as Acetic Acid)
    Nonvolatile Residue ≤0.0005%
    Metallic Impurities Control Limit <0.1 ppb (per element)

    As an accredited LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged under nitrogen in cleanroom-sealed stainless steel containers, ensuring <0.1 PPB purity. Available in 20 liters.
    Container Loading (20′ FCL) Loading 20' FCL of ultra-pure isopropyl alcohol (electronic grade) requires clean, dry container to prevent contamination below 0.1 PPB control limit.
    Shipping Shipping requires strict contamination control to preserve ultra-pure grade (<0.1 PPB). The product is packaged in electro-polished, sealed containers under inert gas, ensuring integrity. Labeled as flammable liquid, transport follows hazardous materials regulations, with temperature stability and traceability documentation to prevent moisture or particulate contamination during transit.
    Storage Store in tightly sealed, high-purity containers (stainless steel or PFA) under inert nitrogen blanketing to prevent moisture and airborne contamination. Keep in a cleanroom or controlled environment, away from heat, sparks, and UV light. Use dedicated, grounded dispensing equipment. Maintain integrity to meet <0.1 PPB specifications and avoid contact with incompatible materials.
    Shelf Life Shelf life is typically 24 months from manufacture when stored sealed, away from light and moisture.
    Application of LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade

    In front-end integrated circuit fabrication, the final rinse preceding gate oxide growth uses LCY Chemical Corporation ultrapure 2-propanol with the supplier-controlled metal cation limit of 0.1 ppb to displace adsorbed water from high-aspect-ratio shallow trench isolation structures without adding ionic contamination. The cleaning sequence following dilute-HF etch or post-CMP oxide polish consists of an intermediate SC-1 bath at 65 ± 5 °C (NH₄OH/H₂O₂/H₂O at 1:1:5 by volume), an ultrapure-water overflow rinse at 22 ± 2 °C until the rinse stream resistivity stabilizes at 18.2 MΩ·cm, a low-flow SC-2 bath (HCl/H₂O₂/H₂O at 1:1:6), and a final rinse under the same resistivity endpoint. The 2-propanol is then delivered as a vapor phase in a single-wafer spin processor; the liquid is filtered through a 0.05 µm PTFE membrane and vaporized into nitrogen at 3–5 vol% under an oxygen-depleted enclosure maintained below 2% O₂. Wafer withdrawal from the final deionized-water meniscus is controlled at 0.5–2.0 mm/s while the surface-tension gradient generated by adsorbed 2-propanol reduces water surface tension from 72.8 mN/m toward 21.7 mN/m at 20 °C, which collapses the rinse-water meniscus without droplet nucleation on gate oxide surfaces. The drying step is conducted at 20 ± 2 °C for 120–180 s, with nitrogen flow at 8–12 L/min; oversaturation with 2-propanol during the first 5 s produces transient wetting that lowers contact angle below 10° on hydrophilic oxide and below 25° on hydrophobic nitride. Process line data indicate that 0.2–0.5% water uptake in the IPA vapor feed increases post-dry defect counts above the 0.15 µm particle threshold; therefore, the delivery vessel is blanketed with nitrogen and the cleanroom relative humidity is held below 55% when the vaporizer is online. The cleanliness specification is anchored to SEMI C63-1212 for trace-metal control in 2-propanol.

    StepTemperatureCritical control parameterFailure mode when exceeded
    SC-1 megasonic bath65 ± 5 °C950 kHz transducer, 400 Woxide microroughening above 70 °C
    UPW overflow rinse22 ± 2 °Cendpoint resistivity 18.2 MΩ·cmresidual ammonium or chloride carryover
    SC-2 ionic desorption60 ± 5 °CHCl/H₂O₂/H₂O 1:1:6metal hydroxide precipitation if pH drifts
    IPA vapor dry20 ± 2 °CN₂ flow 8–12 L/min, withdrawal 0.5–2.0 mm/swater mark formation if IPA injection falls below 3 vol%

    What Ionic Carryover Limit Is Imposed During Pellicle-Mount Surface Conditioning?

    On advanced-node photomask cleaning lines, pellicle mounting of 6025 quartz reticles (152.4 mm × 152.4 mm × 6.35 mm) requires a final organic residue level below the detection threshold of low-flux TOF-SIMS because mobile ions trapped inside the pellicle cavity can migrate during ArF transmissive exposure. The ultrapure 2-propanol is used at full strength for a 10-second spray rinse of the patterned surface after piranha and SC-1 reticle cleaning, and the pellicle frame edge is then hand-swabbed with a 4:1 by volume ultrapure-water:IPA mixture to prevent softening of the pressure-sensitive acrylic adhesive. The cleaning hood operates at ISO 14644-1 Class 4, with HEPA-filtered downflow at 0.45 m/s. For hardened residue on the chrome border, a short 30-second immersion in undiluted 2-propanol at 22 °C is applied only after compatibility testing on the shielding frame, because prolonged contact with siloxane-based pellicle adhesives can extract low-molecular-weight fractions that later form haze on the ArF pellicle membrane. Final inspection is performed with a reticle blank inspection tool using 0.1 µm sensitivity; standard operating procedure rejects any reticle above 0.5 particles/cm² after pellicle mounting. Compliance for sub-mask cleanliness is anchored to SEMI C63-1212 for 2-propanol trace-metal limits and to ArF reticle cleanliness protocols for outgassing species; published numeric data for pellicle adhesive extraction in this specific configuration is limited.

    Magnetic hard disk media prior to diamond-like carbon overcoat deposition are cleaned through a cascade of the present 0.1 ppb 2-propanol dispensed at 0.15–0.25 MPa from PTFE nozzle arrays. The substrate is a 0.635 mm thick glass blank or NiP-plated aluminum blank with 65 mm or 95 mm outer diameter. The cleaning step removes adsorbed plasticizer, fluorinated lubricant-free organics, and submicron alumina particles from the polished substrate after texture and laser zone test. A single-disk spin cleaner rotates at 3000 rpm while the 2-propanol is dispensed at 100% concentration for 20–30 s, followed by a 15-second ultrapure-water flush at the same rotational speed to avoid drying stains on NiP grain boundaries. Non-volatile residue after the combined sequence is monitored by gravimetric analysis per ASTM E1235; the production specification requires less than 0.5 µg/cm² on the final disk before sputtering the amorphous carbon overcoat. The same solvent is used on magnetic head sliders in the head-stack assembly area: a 0.3 mL dose is applied with a cleanroom polyester swab to the air bearing surface, and the slider is then blow-dried with filtered nitrogen at 0.2 MPa. Failure to control metal cations in this cleaning fluid produces a measurable increase in signal-to-noise dropout during spin-stand testing; therefore, the present 0.1 ppb limit is used for all disk and slider contact cleaning. The cleaning zone is maintained at ISO 14644-1 Class 4 and is separated from lubricant dip-coat stations to prevent back-diffusion of perfluoropolyether vapors onto the cleaned substrate.

    When Fiber Optic End Faces Require Non-Volatile Residue Below 1 ng/mm² Before Adhesive Bonding

    The final wipe of a single-mode SC/APC connector end face before adhesive bonding is conducted with 100% ultrapure 2-propanol dispensed from a 0.1 µm filtered pump bottle to prevent microdent contamination on the 8.2 µm core region. The solvent is wicked onto a non-linting polyester foam swab and drawn across the ferrule in a single continuous motion; a second dry wipe removes any liquid meniscus. For cured epoxy residue on the sidewall of the ferrule bore, a 70:30 by volume 2-propanol:deionized-water mixture is used at 35 °C to lower the solvent evaporation rate and soften bisphenol-A epoxy without attacking the glass fiber cladding. A connector inspection microscope with IEC 61300-3-35 acceptance criteria is used to classify scratches, pits, and adsorbed stains; the production line rejects any end face with a non-volatile residue band wider than 5 µm or a scored region exceeding 10 µm in the core zone. After cleaning, connectors are dried with ultrapure nitrogen at 0.05 MPa for 3–5 s and mated immediately inside an ISO 14644-1 Class 5 splicing enclosure. The ionic cleanliness requirement for sealed connector packages is verified by ion chromatography of an extractive rinse; the acceptance limit for total anion residue is 0.5 µg/cm² as sodium chloride equivalent. Use of the present 0.1 ppb metal-cation 2-propanol avoids sodium and potassium migration that would otherwise reduce splice loss stability under damp-heat testing at 85 °C/85% RH per IEC 61300-2-21.

    Thermal Stiction Avoidance in Vapor Drying of High-Aspect-Ratio MEMS Cantilevers

    Release of sacrificial silicon dioxide from a MEMS accelerometer proof mass is performed in concentrated HF vapor followed by a six-cycle ultrapure-water rinse and then a closed-loop 2-propanol vapor drying sequence. The high-aspect-ratio cantilever comb structures, with gap widths from 1.5 µm to 2.5 µm and release length exceeding 50 µm, are prone to capillary stiction if water is allowed to evaporate inside the comb gaps. The present 0.1 ppb 2-propanol is heated to 45 °C in a quartz vapor generator and delivered with nitrogen at 3 L/min for 10–15 min while the chamber temperature is ramped from 25 °C to 55 °C at 5 °C/min. Condensation of 2-propanol on the released structures reduces the liquid surface tension to 21.7 mN/m at 20 °C, and the nitrogen displacement pushes the meniscus out of the comb gaps before drying. The principal batch failure mode is uneven condensation on high-mass proof-mass anchors; this is mitigated by maintaining the IPA vapor concentration at 8–10 vol% in nitrogen and by rotating the wafer at 10 rpm during the initial 2 min. The dried wafers are then transferred under dry nitrogen to the thin-film encapsulation cluster; exposure to cleanroom air above 40% RH is limited to less than 5 min because water re-adsorption on silicon dioxide sidewalls restores capillary force. Final stiction testing is performed by scanning electron microscopy and by electrical pull-in voltage measurement; a shift of pull-in voltage greater than 0.3 V relative to pre-release simulation indicates residual stiction. The resulting wafer-level packaged inertial sensor is then singulated and tested under 85 °C/85% RH environmental stress.

    Deposition uniformity for e-beam evaporated multilayer coatings on laser optics degrades when sub-2 µm dust and adsorbed hydrocarbon films remain on fused silica substrates. A 30 vol% 2-propanol / 70 vol% ultrapure-water mixture is used in an ultrasonic bath at 40 kHz for 180 s followed by a 100% 2-propanol displacement rinse in a vapor degreaser configured for nonchlorinated solvents. The substrates are 25-mm fused silica or zinc selenide witness windows with λ/10 surface flatness at 632.8 nm; the cleaning bench is an ISO 14644-1 Class 5 laminar flow cabinet with 0.45 m/s downflow. After drying with filtered nitrogen, the surface is inspected by dark-field microscopy for particles larger than 1 µm; any component with more than 3 such particles per 25 mm diameter is returned to the ultrasonic line. Hydrocarbon removal is confirmed by FTIR absorption at the C–H stretch region around 2920 cm⁻¹, with acceptance below 0.1% reflectance loss on witness coupons. The cleaned substrates are loaded into an e-beam coating chamber within 15 min to avoid recontamination by cleanroom background siloxanes.

    Implantable PCB Defluxing Requires Ionic Residue Control Below 1.56 µg NaCl/cm²

    Class III implantable pulse generator electronics are cleaned in a two-stage inline spray system using a 75:25 by volume mixture of ultrapure 2-propanol and deionized water heated to 35 °C. The first spray stage at 689 kPa for 10 min removes rosin flux from fine-pitch QFN packages; the second stage applies 100% 2-propanol as a final rinse for 3 min to reduce ionic carryover. Post-clean ion contamination is measured by resistivity of solvent extract per IPC-TM-650 2.3.28 and must remain below 1.56 µg NaCl/cm² per IPC J-STD-001 Class III. The terminal assembly is sealed in a titanium can; ionic residues above this threshold have been correlated with dendrite growth under 85 °C/85% RH biased humidity testing.

    Free Quote

    Competitive LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit < 0.1 PPB) Electronic Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: sales4@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction
    LCY Chemical Corporation supplies an ultra-pure electronic-grade isopropyl alcohol identified on batch certificates as LCY Chemical Corporation Isopropyl Alcohol Ultra-pure (Control Limit <0.1 ppb) Electronic Grade. The material is a C3H8O solvent with CAS registry number 67-63-0 and molar mass 60.10 g/mol. The stated trace-metal control limit is expressed as mass of specified metal per mass of isopropyl alcohol and is held below one part in 10^10 by mass. At 20°C, the neat solvent has a density of 0.785 g/mL, a surface tension of 21.7 mN/m, and a vapor pressure of 4.4 kPa. These physical constants are not grade-specific, but they determine the wetting and evaporation behavior on wafer surfaces during spin-rinse and vapor-dry sequences. The product is positioned for front-end semiconductor cleaning, final rinsing, and drying after ultrapure-water processing. Unlike technical or laboratory isopropyl alcohol grades that may share the same CAS number, this material is supplied with a trace-metal ceiling intended for processes where mobile-ion contamination can degrade device yield.

    What Analytical Verification Is Applied to the <0.1 ppb Control Limit?

    Verification of the <0.1 ppb control limit is performed by inductively coupled plasma mass spectrometry on samples collected from the packaged container, with sample preparation executed under ISO Class 5 or equivalent cleanroom conditions. The accepted semiconductor-industry consensus document for isopropyl alcohol quality is SEMI C12; while product-specific clause mapping requires the batch certificate, routine wet-process control uses ICP-MS to resolve individual alkali, alkaline-earth, and transition-metal species at part-per-trillion detection limits. The analytical method is sensitive to environmental contamination because sodium, iron, and zinc can enter the sample from glassware, syringe needles, or benchtop air at levels above the control limit. Sampling hardware must therefore be dedicated and flushed with ultrapure isopropyl alcohol prior to collection. False positives from improper sampling appear on incoming inspection benches as intermittent sodium, iron, and zinc excursions that do not repeat after container re-sampling. The batch certificate typically reports each specified element rather than a single aggregated “total metals” value, because the process-relevant risk is element-specific: sodium and potassium affect mobile-ion charge, while iron, copper, and zinc can promote surface defects and electrochemical degradation. The absence of an element on the certificate should not be interpreted as a zero concentration; it indicates that the element was not included in the certified analytical panel.

    Cleanroom Solvent Function in Single-Wafer and Batch Surface Preparation

    Application of LCY ultra-pure isopropyl alcohol occurs in single-wafer spin processors, batch immersion tanks, and spray-in-air tools where patterned wafers require low-surface-tension rinsing without introducing ionic residues. The solvent displaces aqueous cleaning chemistries from high-aspect-ratio features and supports Marangoni-assisted drying as water is withdrawn from the wafer surface. In photoresist strip and edge-bead removal sequences, the solvent is used neat or as part of a co-solvent blend at dispense temperatures from 20°C to 40°C. The low metal background prevents post-strip metal decoration, which is critical on exposed copper and cobalt interconnect surfaces. For advanced packaging and bumping processes, the material removes flux residues from solder bump structures, where residual cation contamination above 0.1 ppb can accelerate under-bump metallization corrosion. The product dissolves polar organic residues, but it is not a replacement for alkaline cleaners when cured epoxy, novolac, or heavily cross-linked photopolymer films require aggressive chemical attack. Published data for LCY-specific dissolution rate coefficients on specific photopolymer films is limited; process qualification should therefore be performed in the actual spray chamber or immersion tool geometry. In wafer drying, the lower surface tension of isopropyl alcohol relative to ultrapure water reduces capillary forces within narrow resist lines and improves the drying margin for pattern collapse. The same property is relevant to backside cleaning, where moisture retention at the wafer bevel or edge-exclusion zone can create downstream particle transfer.

    When Relative Humidity Exceeds 60% and Flammable Storage Intersect

    Storage and dispensing systems for the LCY ultra-pure grade are configured to exclude atmospheric moisture and particles because the solvent is hygroscopic and can absorb water from humid air during open-port transfer. At relative humidity above 60%, open dispensing increases water uptake and can shift the evaporation rate sufficiently to alter final drying time in single-wafer chambers. The resulting watermarks are observed on patterned wafers with fine-pitch structures and on metal surfaces where slow evaporation leaves residue rings. Engineering controls include dry nitrogen blanketing at 0.05 psig to 0.15 psig, point-of-use filtration through 0.05 µm or 0.1 µm fluoropolymer membranes, and recirculating dispense loops that prevent stagnant solvent from accumulating corrosion products. The material is flammable, with a closed-cup flash point near 12°C; storage must therefore comply with local fire codes, and transfer must avoid open containers in areas where electrostatic discharge or heated tool surfaces generate ignition sources. Incompatibilities include strong oxidizers, acid mixtures, and halogens. The product should not be blended with nitric acid or hydrogen peroxide unless the process is designed for controlled organic-aqueous reaction and heat removal. In semiconductor wet stations, segregated drain lines and exhaust plenums are used to keep solvent vapor away from oxidizer storage and chemical mixing modules.

    Physical Property Reference Points and Incoming Inspection Criteria

    The following table lists physical constants for the neat solvent and the product-specific trace-metal control limit.
    ParameterValueReference / test designation
    CAS registry number67-63-0Chemical identity
    Molecular formulaC3H8OChemical identity
    Molar mass60.10 g/molCalculated from atomic weights
    Density at 20°C0.785 g/mLASTM D4052
    Boiling point at 101.3 kPa82.5°CLiterature value
    Closed-cup flash point12°CASTM D56
    Surface tension at 20°C21.7 mN/mLiterature value
    Vapor pressure at 20°C4.4 kPaLiterature value
    Trace-metal control limit<0.1 ppbICP-MS after SEMI C12 sampling
    Product-specific lot data for water content, non-volatile residue, acidity, and particle counts must be compared against the batch certificate and the customer’s incoming specification. The <0.1 ppb control limit is not a bulk-property specification but a trace-element threshold; reported values may vary with the analytical laboratory’s element list. For incoming inspection, many manufacturing sites use a reduced panel of mobile-ion species—sodium, potassium, calcium, magnesium, iron, copper, zinc, and chromium—rather than a full elemental scan. Wafer fabs using the material for gate-level cleaning commonly require the certificate of analysis to show actual numerical results below 0.1 ppb for each specified metal instead of a pass/fail statement. Particle specifications are handled separately because sub-0.1 µm particle counting requires optical particle counters calibrated for low-conductivity solvents. Production-scale failure modes associated with electronic-grade isopropyl alcohol typically involve particle release from dispense lines, water uptake during drum transfer, and trace-metal excursions from inadequate container preparation. On a batch immersion line, a single improperly rinsed 200 L drum can deliver iron above the control limit and shift the bath’s particle loading, causing front-end tool monitors to detect defect density increases on blanket oxide wafers. Equipment qualification therefore includes a worst-case dispense test using particle counters with 0.04 µm sensitivity and an initial purge volume sufficient to displace the dead volume of the filter housing and nozzle. The product is not permitted for direct injection into ultrapure water loops unless the loop materials and backflow prevention are rated for organic solvents; solvent back-diffusion into ultrapure water can damage downstream UV sterilizers and degrade water quality. The operational boundary for the LCY ultra-pure grade is therefore defined by approved cleanroom dispense materials, closed transfer, and lot-by-lot trace-metal verification rather than by intrinsic chemical stability. In high-volume manufacturing, batch-to-batch variance is monitored by trending the specific metal values on the certificate of analysis over successive lots, because a gradual upward drift, even when the control limit is not breached, can indicate contamination from a shared packaging line or a saturated ion-exchange polishing bed.