    Specifications
    HS Code 960714
    Chemical Name Isopropyl Alcohol
    Chemical Formula C3H8O
    Cas Number 67-63-0
    Molecular Weight 60.10 g/mol
    Assay Purity ≥99.9%
    Water Content ≤0.1%
    Appearance Clear colorless liquid
    Color Apha ≤10
    Boiling Point 82.4°C
    Melting Point -88.5°C
    Flash Point 11.7°C
    Vapor Pressure 20 C 4.4 kPa
    Refractive Index 20 C 1.377
    Specific Gravity 20 20 C 0.785
    Evaporation Rate N Butyl Acetate 1 ≈2.1
    Residue After Evaporation ≤5 ppm
    Acidity As Acetic Acid ≤10 ppm
    Chloride Content ≤0.5 ppm
    Sulfate Content ≤0.5 ppm
    Metallic Impurity Content ≤1 ppm per metal

    As an accredited Dow Isopropyl Alcohol Electronic Grade factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in clean, sealed containers such as 1-gallon and 5-gallon jugs, ensuring high-purity electronic-grade isopropyl alcohol remains contamination-free.
    Container Loading (20′ FCL) Loading 20′ FCL with Dow Isopropyl Alcohol Electronic Grade; drums/ISO tanks secured, proper labeling, ventilation, and safe segregation ensured.
    Shipping Dow Isopropyl Alcohol Electronic Grade ships as a flammable liquid (UN1219, Class 3). It must be transported in grounded, properly labeled containers with secure closures, away from ignition sources. Use approved packaging and follow DOT/IMO/ADR regulations. Ensure documentation, hazmat placards, and spill containment materials accompany shipments.
    Storage Store Dow Isopropyl Alcohol Electronic Grade in tightly sealed, original containers in a cool, dry, well-ventilated area away from heat, sparks, and open flames. Keep containers grounded and bonded to prevent static discharge. Avoid contact with strong oxidizers. Use inert gas blanketing to maintain purity, and ensure storage temperatures remain stable.
    Shelf Life Shelf life is typically 24 months from production when stored unopened in original containers under recommended conditions.
    Application of Dow Isopropyl Alcohol Electronic Grade

    On 300 mm single-wafer clean tracks, undiluted Dow Isopropyl Alcohol Electronic Grade is introduced after dilute SC1 and SC2 baths as the final rinse before Marangoni drying. The solvent lowers air-water interfacial tension from 72.8 mN/m for water to approximately 21.7 mN/m at 20 °C, generating the surface-tension gradient required to pull rinse water from shallow-trench features, high-aspect-ratio vias, and photoresist sidewalls. Equipment commonly comprises an immersion wet bench, a single-wafer spin processor, or a batch horizontal dryer. On a single-wafer cup, the final rinse flow is typically 0.8 L/min to 1.2 L/min per 300 mm wafer, with wafer rotation between 800 rpm and 1500 rpm. The cleaning ratio is 100 vol% electronic-grade IPA; point-of-use DI water dilution is not applied in the final rinse when sub-32 nm defect control is required because water content above the SEMI C7 electronic-grade limit raises residual water-spot formation after droplet expulsion. In batch vapor dryers, the solvent is supplied to the vapor zone at 45 °C to 55 °C, and cassette withdrawal speed is constrained to 0.5–2.0 mm/s to prevent meniscus break. Compliance is documented against SEMI C7, with certificate-of-analysis reporting chloride, sodium, and iron each below 50 ppb and non-volatile residue not exceeding 10 ppm. Terminal outputs are logic, memory, and foundry wafers for gate-all-around transistor nodes, DRAM stacked-capacitor structures, and through-silicon-via interposers.

    How Is Edge-Bead Residue Thickness Managed in Photoresist Processing?

    The edge-bead dispense sequence differs from front-end wafer cleaning because the solvent is applied at a precisely defined radial zone during the same spin cycle as resist coating or immediately before developing. Dow Isopropyl Alcohol Electronic Grade is forced through an edge-bead removal nozzle at 0.05 MPa to 0.20 MPa back pressure, with the nozzle positioned 1 mm to 3 mm from the wafer edge while the chuck rotates at 500–1200 rpm. The dispense liquid remains undiluted because photoresist dissolution at the edge is solubility-driven, and DI water dilution above 10 vol% slows removal of high-molecular-weight novolac or acrylic resists. The process target is a residual edge bead width of less than 0.2 mm after develop inspection on automated optical defect scanners. Metal ions are the critical contamination vector: potassium and sodium in lower-purity solvent grades can alter photoresist dissolution rate and produce post-develop residue. Compliance is held to SEMI C7 electronic-grade limits, with water content not exceeding 500 ppm and particle counts at 0.5 µm and larger controlled to 25 particles/mL or fewer. Terminal products include 248 nm and 193 nm lithography stacks, EUV resist underlayers, and wafer-level packaging redistributed-layer patterns.

    No-clean solder paste residues on underside stencil foils are removed in closed-loop under-stencil wash systems using Dow Isopropyl Alcohol Electronic Grade blended with point-of-use DI water at 60:40 to 100:0 volume ratio, depending on solder paste vehicle rheology. Rosin-based pastes may tolerate 40 vol% DI water without residue redeposition, while fully synthetic no-clean pastes with high-thixotropy agents require undiluted solvent. Wash cabinet temperature is held at 35 °C to 45 °C; higher temperatures increase vapor pressure and fire load without measurably improving flux dissolution in short-cycle wiping. The solvent is dispensed through a reciprocating spray bar at 0.25 MPa to 0.4 MPa onto the foil, and the stencil is vacuum-dried within 15 s to 30 s to prevent paste tack loss on the next print stroke. Process-compatible soft goods are limited to EPDM, PTFE, and stainless-steel wetted parts; natural rubber seals and unlined aluminum reservoirs are not used because trace metal leaching can defeat the electronic-grade purity. Compliance for cleaned assemblies is verified by IPC-TM-650 method 2.3.25 for ionic cleanliness, with acceptance below 1.56 µg/cm² NaCl equivalent for many class 3 assemblies, and by visual inspection to IPC-A-610. Terminal products are surface-mount PCBA subassemblies for automotive engine control modules, aerospace flight instrumentation, and industrial motor drives.

    Application segmentPrimary standard or methodCritical parameterAcceptance limit
    Semiconductor front-end cleaningSEMI C7Chloride, sodium, iron<50 ppb each
    Lithography edge-bead and backside rinseSEMI C7Water content≤500 ppm
    SMT stencil washingIPC-TM-650 2.3.25Ionic cleanliness≤1.56 µg/cm² NaCl equivalent
    Display mask pre-cleaningISO 14644-1 Class 4Airborne particles ≥0.5 µm352 particles/m³
    Fiber optic connector end-face preparationIEC 61300-3-35Core, cladding, adhesive, contact zone defectsPass/fail zone map
    HDD head-slider cleaningSEMI C7Non-volatile residue≤10 ppm

    Fine Metal Mask Pre-Coating Rinse for OLED Vacuum Deposition

    Organic residue breakthrough occurs when display substrate cleaning uses undiluted Dow Isopropyl Alcohol Electronic Grade in a two-stage ultrasonic line: 40 kHz irradiation in a first immersion vessel, followed by a second overflow rinse and warm vapor drying at 50 °C. The blend ratio remains 100 vol% IPA for fine metal mask cleaning because water droplets trapped in mask apertures can produce shadowing defects during red-green-blue layer evaporation. For rigid ITO glass pre-cleaning, some lines run 85:15 IPA/DI water to limit evaporative cooling and improve particle suspension; however, the final rinse must revert to undiluted electronic-grade IPA to maintain non-volatile residue below 10 ppm. Process control includes replenishment of the immersion bath after 8 h of use or after a defined panel count, because dissolved organics from mask alignment frames can accumulate and re-deposit during drying. Compliance is tied to SEMI C7 and cleanroom classification ISO 14644-1 Class 4 or better; particle counts on the substrate surface are monitored before sputter deposition. Terminal outputs include OLED smartphone and tablet panels, flexible AMOLED modules, and fine metal mask maintenance for RGB selective deposition.

    Single-mode connector end-face preparation before return-loss testing uses lint-free wiping saturated with Dow Isopropyl Alcohol Electronic Grade without dilution. The saturation level is controlled at 0.3 mL to 0.5 mL per 2.5 mm ferrule wipe to avoid wick-up into the fiber jacket, which can leave a drying film and attract particulates. A single continuous figure-eight wipe across the end face removes organic polishing compound and uncured epoxy residue; IEC 61300-3-35 zone maps then define pass/fail criteria for core, cladding, adhesive, and contact zones. The electronic-grade solvent is used because chloride and sodium contamination on the end face can migrate under humidity and increase optical return loss. The process window is narrow: wiping with insufficient fluid leaves scratches, while over-wetting transfers adhesive residue into the core zone. Terminal products include single-mode and multimode patch cords, MPO/MTP harness assemblies, and fiber-optic transceivers.

    When Head-Slider Cleaning Requires Sub-0.1 µm Particle Control

    When head-slider bars are transferred from slicing to lapping lines, Dow Isopropyl Alcohol Electronic Grade is applied in an ISO 14644-1 Class 4 cleanroom immersion and spin-rinse sequence to remove diamond slurry residues. The solvent must be undiluted; water blends are excluded because residual water on AlTiC slider surfaces can form oxide films that shift magnetic spacing. A typical production benchtop uses a 0.5 L stainless-steel immersion bath with 40 kHz ultrasonic energy for 120–180 s, followed by a filtered nitrogen blow-off at 0.35 MPa. Liquid-borne particles are specified at 0.1 µm and larger, with counts checked before each lot; non-volatile residue is held below 10 ppm to avoid deposition on the air-bearing surface. Compliance is evaluated by SEMI C7 and by surface energy shift measured lot-to-lot. Terminal products are hard disk drive head-gimbal assemblies for enterprise nearline drives.

    Free Quote

    Competitive Dow Isopropyl Alcohol Electronic Grade prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: sales4@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    DOW™ Isopropyl Alcohol, Electronic Grade is a high-purity, low-water isopropyl alcohol supplied under the grade descriptor rather than a single numeric model code. Regional stock-keeping part numbers are generated from package size, fill volume, and container material; the technical identity remains CAS 67-63-0 and the electronic-grade lot certificate is the binding specification. In device fabrication facilities, the solvent is qualified for post-ash residue removal, wafer edge-bead lift-off, and final spin-bath rinsing where mobile-ion contamination must remain below the gate-oxide damage threshold. The electronic-grade designation differs from general-purpose solvent in four measurable ways: water concentration, cation and transition-metal contamination, submicron particulate burden, and nonvolatile residue after evaporation.

    The product is commonly packaged in 1 L, 2.5 L, 4 L, and 20 L containers of borosilicate glass or fluoropolymer-lined closures. Each lot is released with a certificate of analysis that includes GC-FID assay on a water-free basis, Karl Fischer water content, nonvolatile residue, chloride and sulfate screening, ICP-MS trace-metal screen, and optical particle counting at 0.2 µm or smaller. The package and seal configuration is intended to reduce leachable plasticizer uptake and particle generation during repeated decanting under a purge hood.

    How Does Electronic-Grade IPA Differ from Technical-Grade and Reagent-Grade Isopropyl Alcohol?

    The primary difference is not the solvent chemistry; the principal component is the same branched alcohol, and it retains the same thermodynamic solvent parameters such as a closed-cup flash point of approximately 12 °C and a normal boiling point of 82.6 °C. What changes is lot-level contamination control. Reagent-grade material is typically specified by assay and water content but may carry ppm-level metal impurities from glass-lined storage and conventional filling lines. Technical-grade material may contain 0.5–1.0 wt% water and measurable nonvolatile residues because it is produced for cleaning, thinning, or general-purpose solvent use without a semiconductor contamination budget. Electronic-grade material is filled in dedicated cleanroom-adjacent lines with filtered product, and the certificate of analysis includes cation and transition-metal limits at the ppb level, because residual sodium or potassium can drift into gate oxides or change the electrical performance of compound semiconductor surfaces.

    Grade Assay, wt% min Water, wt% max Trace-metal control Particle control
    Electronic grade ≥99.99 on water-free basis ≤0.02 ICP-MS ppb-level cation screen; commonly ≤10 ppb per element for Na, K, Fe, Cu, Zn OPC at 0.2 µm with lot-release count limit
    Reagent/ACS ≥99.5 ≤0.5 ppm-level by ICP-OES; element-specific limits vary not routinely controlled
    Technical/industrial ≥99.0 typical ≤1.0 not specified not specified

    In analytical qualification, the certificate of analysis should be reviewed for the reporting basis of trace metals. Some suppliers report as-is values against the diluted sample matrix; others normalize to the neat solvent. The difference can be significant when a laboratory dilutes the solvent with ultrapure water containing its own background level of sodium. For a cation screen at ≤10 ppb per element, inductively coupled plasma mass spectrometry with collision/reaction cell technology is used because it reduces polyatomic interferences for iron and potassium. The certificate should also specify whether particle counts are taken immediately after filling, because particle rebound and agglomeration in non-fluoropolymer containers can alter counts within the first 24 h after transportation.

    Batch-to-batch variation in nonvolatile residue can originate from the final distillation column reflux ratio or from the age of filter membranes in the packaging line. End-user statistical process control can track nonvolatile residue per lot using ASTM D1353-13; a shift above the typical 5 ppm threshold may indicate filter breakthrough rather than a distillation change. Packaging-line equipment such as stainless-steel pumps with mechanical seals can contribute particle shedding if seal wear occurs. Certificate data alone may not reveal intermittent particle excursions if individual lot analysis is composited. For this reason, semiconductor facilities commonly perform incoming point-of-use particle counting before releasing a drum to production.

    When a Batch Is Qualified for Spray-Tool Rinsing, the Drying Curve, Not the Assay Alone, Becomes the Control Limit

    For a single-wafer spin processor with an IPA-based rinse nozzle, the critical process parameter is not usually the principal assay, because a variation between 99.99% and 99.95% may produce no measurable change in dissolution rate for organic residues. The critical parameter is the water concentration and its effect on the final evaporation sequence. Isopropyl alcohol has a surface tension of approximately 21.7 mN/m at 20 °C and a viscosity near 2.3 mPa·s; this low surface tension enables it to displace water from high-aspect-ratio trenches and to create a surface-tension gradient during drying. If the water concentration in an opened container rises above the qualification limit, the final rinse can leave drying stain residue on hydrophobic low-k films or on silicon nitride passivation. A reported production-scale corrective action for intermittent watermarks after final rinse is point-of-use Karl Fischer sampling from each opened 4 L bottle and replacement of the container when water content exceeds 0.05 wt% rather than waiting for the nominal shelf-life label. The same limit may be tightened to 0.02 wt% when the rinsing process precedes a metal lift-off or gate metal evaporation step.

    This drying behavior is why electronic-grade material is sometimes specified by end users to a maximum water level of 0.02 wt% or 0.005 wt%, even though the base ASTM D770-21 specification for isopropyl alcohol does not impose semiconductor-level water control. A closed-loop distillation system can recover used IPA, but the isopropanol-water azeotrope at 87.7 wt% isopropanol and approximately 80.4 °C establishes a practical concentration limit for simple atmospheric distillation. Drying columns or molecular sieve polishing are required to return recycled solvent to electronic-grade water content; otherwise the recovered stream is best assigned to less critical cleaning services.

    In Marangoni drying, the process uses a vapor of isopropanol carried by nitrogen to lower the surface tension at the water meniscus. Water has a surface tension of approximately 72.8 mN/m at 20 °C, and the IPA-rich region at the meniscus can be much lower. The gradient induces liquid flow away from the wafer surface, and the wafer is withdrawn slowly. The material's purity matters in this operation not because of the organic assay, but because nonvolatile residues and metal ions remain on the surface after the water-IPA mixture drains. A typical production setting monitors final wafer surface particle counts with a laser scanning system after the dry step, and a rise in particle adders is often traced back to hydrocarbon residue from an aging vaporizer heater. The lot certificate should therefore include a low nonvolatile residue limit, and the vaporizer wetted surfaces should be cleaned with a separate electronic-grade alcohol rinse on a preventative maintenance schedule.

    At point-of-use, the solvent is commonly dispensed through a fluoropolymer filter capsule rated at 0.05 µm or 0.1 µm absolute to remove any particle contamination generated by the container closure or the dispense pump. Because the product has a viscosity near 2.3 mPa·s, the pressure drop across a 0.05 µm capsule at typical flow rates is modest; however, the dispense system should not rely on gravity when the fluid is cold. Temperature control near 20–25 °C maintains consistent flow and reduces condensation of ambient water into the solvent from chilled lines.

    In automated dispense modules, wetted materials must be stainless steel, fluoropolymer, or high-density polyethylene that has been pre-rinsed with filtered electronic-grade IPA. Flexible polyvinyl chloride tubing and acrylic flow-meter bodies are incompatible with long-term contact because plasticizer and oligomer leaching can raise nonvolatile residue and reintroduce hydrocarbon contamination after the final filter. The product should not be blended with concentrated sulfuric-peroxide mixtures or strong oxidizers under uncontrolled conditions because isopropyl alcohol is a flammable organic solvent with a lower flammable limit of approximately 2.0 vol% in air. Grounding and bonding of metallic transfer containers is required; vapor can travel to ignition sources, and the closed-cup flash point is near 12 °C. Local exhaust ventilation should maintain airborne concentrations below the relevant occupational exposure limit; ACGIH lists an 8-hour TWA of 200 ppm for isopropanol, although user site permits may apply lower internal limits in cleanroom subfab compartments.

    For vapor degreasing or heated rinse modules, the operating boundary is set by the flammability range and the heating element surface temperature. The lower flammable limit is approximately 2.0 vol% and the upper flammable limit is approximately 12.7 vol% at 25 °C. Maintaining oxygen below 10 vol% by nitrogen blanketing is a common control for sealed cleaning modules. Electrical interlocks, ventilation fail-safe, and continuous lower-explosive-limit monitoring are specified on production-scale tanks. The product itself does not require special grounding beyond normal flammable-liquid transfer practice, but transfer rate and fill-line velocity should be limited to avoid static charge accumulation, particularly in nonconductive fluoropolymer containers.

    In printed circuit assembly and electronics cleaning, the electronic-grade material is used for stencil cleaning, flux removal, and capillary removal of no-clean residues from fine-pitch components where ordinary technical alcohol can leave white residues or ionic contamination. For such applications, the nonvolatile residue specification of 5 ppm or lower is more important than the trace-metal level. A high-purity batch can still produce white residues if the cleaning equipment itself is contaminated with tin oxide or solder paste from prior products; the solvent cannot correct a contaminated wash tank or wipe medium. Maintenance of the dispense path and use of point-of-use cartridge filters rated at 0.2 µm absolute are required to maintain the particle and residue benefit of the incoming solvent.

    Cleaning of stencils and misprinted boards uses electronic-grade IPA in spray-under-immersion or ultrasonic tanks. For fine-pitch apertures below 0.4 mm, mechanical agitation is required because surface wetting alone does not remove solder paste from the aperture walls. The solvent dissolves flux components but does not liquefy tin oxide or hardened paste; therefore an initial dry wipe or presoak step is used before immersion in electronic-grade IPA. In high-volume lines, the bath is changed based on the volume of paste removed rather than visual color, because clear liquor can still contain ionic and nonvolatile residues above the incoming product specification.

    After cleaning, printed board assemblies can be tested according to IPC-TM-650 Method 2.3.25 for ionic residues. The test measures the resistivity of the extraction solution and cannot distinguish ionic load from incoming solvent from ionic load from process surfaces; therefore a blank extraction with the same solvent lot should be run when troubleshooting a high reading. This is particularly relevant when a site converts from technical-grade IPA to electronic-grade IPA and expects lower ROSE values without first cleaning the wash tank, spray manifold, and recirculation filters.

    Storage conditions affect the electronic-grade benefit. Containers should remain closed when not in use, with nitrogen or dry-air pad gas if the package is repeatedly opened in a humid cleanroom or assembly environment. Isopropanol is hygroscopic; headspace exchange with ambient air carries moisture into the container, and the rate depends on the free surface area, container volume, and local relative humidity. Because moisture uptake is a diffusional process with uneven concentration near the liquid surface, sampling from the top of a partially filled drum without agitation can understate the average water content. Point-of-use Karl Fischer titration or at-line near-infrared analysis is preferred to composite sampling when a dry-final-rinse process is under statistical control. In a control test with a partially filled 4 L bottle opened for 30 min under 45% RH, static headspace moisture can raise water content by measurable amounts depending on air circulation and temperature; published data for this specific configuration is limited, so each site should validate its own open-container time.

    Optical fiber connectors can be cleaned with fiber-grade isopropanol, but electronic-grade material is used where residue-induced insertion loss is a concern. In production environments, the solvent is applied to a lint-free swab and then inspected under 400× magnification for particle transfer. The absence of nonvolatile residue in electronic-grade material means that residue on the optical end face after cleaning is process debris rather than solvent film. Electronic-grade isopropyl alcohol is not a universal cleaner for all fluorinated optical coatings; compatibility with the specific cable or component manufacturer should be confirmed before use.

    Batch-to-batch variation in metal content is often evaluated by ICP-MS after dilution. The analytical blank is prepared from ultrapure water that has been filtered through 0.05 µm and blanked against the same nitric acid matrix used for sample preparation. For sodium, potassium, iron, copper, and zinc, trending individual elements on a statistical process control chart is more informative than tracking total metals, because different columns and filling-line elastomers can release different cations. If one element increases but remains below the specification, it may identify the onset of a packaging component failure or an exchanger bed nearing replacement. Wafer fabs may set internal control limits tighter than the supplier certificate, for example ≤5 ppb for sodium and ≤2 ppb for copper, to protect front-end process modules.

    For all applications, electronic-grade IPA is not a formulated cleaning liquid; it is a single-component solvent. The boundary of its usefulness is the dissolution of rosin-based, organic, or mildly polar residues and the displacement of water from surfaces. It does not remove inorganic oxides, carbonized deposits, or cross-linked polymer films without mechanical action or a preceding alkaline or acidic clean. That limitation is intentional because it means the solvent leaves no inhibitor or chelator residue of its own; when an end user adds a corrosion inhibitor to a rinse bath, the benefit of the electronic-grade purity is compromised unless the inhibitor is also fully volatile and qualified for the final surface. For semiconductor and electronics assembly, the material is selected when the cleaning stage sits near the functional electrical surface and the risk of ionic or particulate carryover cannot be accepted from reagent or technical grades.